6eCSM
6 Electric Current Sensing Module
Full Lighting Controls - On & Off System

The Current Sensing method of this module is based on CT type of sensing method, and the Current Sensing is 1% accuracy for the accurate current measurement is possible.
Main Feature
…Measure Current Consumption by each Circuit (Max 20A)
…Usage Integration (Daily, Monthly)
…Storage & Report for Electricity Usage (Up to 32 days at present, 16 months storage)
…Enable/Disable function for Demand Control.
…Data Line that connects to FULL 2 Wire BUS method.
…Can be controlled during Download & Database modification operation
…Each Control Panel has Global Stand Alone function.
…The continuous operation is able even when Central Control System is disabled
…To SCU (Comm. Device) up to maximum of 999 EA. can be connected (with xRM)
…Usage Integration (Daily, Monthly)
…Storage & Report for Electricity Usage (Up to 32 days at present, 16 months storage)
…Enable/Disable function for Demand Control.
…Data Line that connects to FULL 2 Wire BUS method.
…Can be controlled during Download & Database modification operation
…Each Control Panel has Global Stand Alone function.
…The continuous operation is able even when Central Control System is disabled
…To SCU (Comm. Device) up to maximum of 999 EA. can be connected (with xRM)
Operation
This Current Sensing Module is connected to 6sRM and can perform the Current Sensing function in conjunction with ON/OFF control for 6sRM. It also has the DEMAND control function for Current Limit Cut-Off Control. Each Current Sensing Module is consisting of Current Sensing Board and Communication Board as configured for integrated structure. Therefore, if the 6eCSM is additionally installed in the Lighting Control Panel where only the previous 6sRM is applied, the current consumption of each really circuit can be measured.
Networking
It is connected through 6sRM and UART communication (serial communication between each CPU) and operates as 6eCSM when connected. Also, the previous 6sRM is connected to the Data Line of the ELC System and it is connected and operated with up to 999 ea. of 6sRM (including 6eSCM) for address up to 000-999.
Specification
…6ea. – LED Status Indicators
…6ea. – 16A Latching Relay
…6ea - Current sensing IC: 20A AC220V
…Full 2-Wire Communication
…Address Setting: 1 ~999
…32Bit Stand Alone Control Processor
…2ea - Digital Input
…Operation Condition: -10 ~ 60°C
…AC/DC24V, 50/60Hz, 7VA
…6ea. – 16A Latching Relay
…6ea - Current sensing IC: 20A AC220V
…Full 2-Wire Communication
…Address Setting: 1 ~999
…32Bit Stand Alone Control Processor
…2ea - Digital Input
…Operation Condition: -10 ~ 60°C
…AC/DC24V, 50/60Hz, 7VA
Dimension of Layout
System Diagram
Connection Diagram